| FTDX1200 Operating Manual | Page 115 |
|
037 MOX Function: Enables/disables MOX operation. Available Values: ENABLE or DISABLE Default Setting: ENABLE
038 RF SQL VR
039 CAT RATE
040 CAT TIME OUT TIMER
The Time-Out Timer shuts off the CAT data input after a continuous transmission of the programmed time.
041 CAT RTS
042 MEM GRP
043 QUICK SPLIT FREQ
044 TXW DIAL SELECT
VFO-A: The TX frequency is tuned with the Main Tuning Dial knob.
VFO-B: The TX frequency is tuned with the [VFO-B/CLAR] knob.
045 TX TIME OUT TIMER
The Time-Out Timer shuts off the transmitter after continuous transmission of the programmed time.
|
046 µTUNE DIAL STEP Function: Selects the µTune mode. Available Values: DIAL STEP-1 or DIAL STEP-2 Default Setting: DIAL STEP-1 DIAL STEP-1: Activates the µTUNE system using "COARSE" steps of the [VFO-B/CLAR] knob (2 steps/click) on the 7 MHz and lower amateur bands. On the 10/14 MHz bands, "FINE" [VFO-B/CLAR] knob steps will be used (1 step/click). DIAL STEP-2: Activates the µTUNE system using "FINE" steps of the [VFO-B/CLAR] knob (1 step/click) on the 14 MHz and lower amateur bands. ADVICE: If an optional RF µTuning Kit is not connected, this adjustment has no effect.
047 MIC SCAN
048 MIC SCAN RESUME
PAUSE: The scanner will hold until the signal disappears, then will resume after one second.
TIME: The scanner will hold for five seconds, then resume whether or not the other station is still transmitting.
049 FREQ ADJ
To calibrate the frequency of your radio, you will need a freqency counter or set your receiver to one of the time standard frequencies such as WWV or WWVH.
1. Turn off both RX CLAR and TX CLAR function, before adjustment.
2. Tune the radio to 15,000.00 MHz with CW-USB mode, then adjust the AF knob to comfortable listening level.
3. Enter Set Menu Item "049 FREQ ADJ", and then adjust the [VFO-B/CLAR] knob so that the BAR display is illuminated in the center on the meter.
|